Adjustments
Ice Bridge Thickness
Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments
are not covered by warranty.
Shut machine off.
Access the ice thickness sensor.
Check gap between metal tip and evaporator grid. Standard gap is 7/32 inch. To set 7/32" drill bit between
sensor tip and evaporator to check. Adjust gap using adjustment screw.
Restart unit and check ice bridge. Repeat as needed.
1/8 to 3/16
inch bridge
Too Thin
Too Thick
Correct Correct