Adjustments

Ice Bridge Thickness

Caution: Do not make the bridge too thin or the machine will not harvest properly. Bridge thickness adjustments

are not covered by warranty.
Shut machine off.
Access the ice thickness sensor.
Check gap between metal tip and evaporator grid. Standard gap is 7/32 inch. To set 7/32" drill bit between

sensor tip and evaporator to check. Adjust gap using adjustment screw.
Restart unit and check ice bridge. Repeat as needed.

1/8 to 3/16

inch bridge

Too Thin

Too Thick

Correct Correct
Small

Medium

Adjustment Screw