Electrical Component Details

Liquid Line Valve
• Remote only. Opened by the controller to start a freeze cycle. Closed to shut unit off. Line voltage coil.

Hot Gas Valve(s)
• Operated by the controller in parallel with the harvest assist solenoid. Cycles on and off at the beginning of a

restart. Energized throughout the harvest cycle. Line voltage coil.

Controller
• Senses ice thickness, water level, water temperature, discharge temperature. Controls compressor contactor,

fan motor, water pump, inlet water valve, hot gas valve, purge valve, harvest assist solenoid. Indicates status

and component operation. 12 volt.

Transformer
• 12 volt secondary, supplies power to controller only.

Water Level Sensor
• Three probe conductivity sensor. Bottom probe is common, mid probe is refill sump, top probe is full sump.

Refill can occur at any time.

Ice Thickness Sensor
• Single wire conductivity sensor. Circuit made from controller to ground to controller when water contacts a

probe suspended over ice plate. Signals ready for harvest.

Curtain Switch(es)
• Magnetic reed switch. Normally open, switch is closed when magnet is nearby. Models with two evaporators

have two curtain switches. Single switch can be connected to either J8 or J7 of controller. Curtains may be

removed in the freeze cycle without affecting controller operation. A curtain removed during harvest will cause

the controller to terminate harvest and shut the unit off. Two curtain models require both curtains to open to

terminate harvest, and if either one remains open for 30 seconds that signals the controller to shut the unit off

on bin full.

Water temperature sensor.
• Thermistor inserted into the water pump discharge hose. Reported temperature used by the controller to

determine anti-slush cycle start time.