beautypg.com

Scotsman Prodigy Series User Manual

Page 49

background image

January 2015 Page 49

Diagnostics – Remote Air Cooled

No ice

Problem

Likely Cause

Probable Solution

No power to unit

Power disconnected Check breaker or fuse.

Reset or replace, restart and check

No power to controller

Transformer open

Replace transformer

Shut down on maximum

water fill time

Water shut off

Restore water supply

Shut down on maximum

freeze time

Water leak

Check purge valve, curtain, sump, pump

hose

Dirty condenser

Clean condenser

Restricted location, intake air too hot

Have condenser moved

Ice thickness sensor dirty or disconnected

Check ice thickness sensor probe

Water distributor dirty

Remove and clean water distributor

Inlet water valve leaks through during freeze

Check inlet water valve

Connected to hot water

Check for bleed thru from / missing check

valve in building water supply

Incomplete harvest

Check harvest system

High pressure cut out opened

Check fan motor pressure control, check

fan motor, check controller using test

mode

Fan motor not turning

Check fan motor, check fan blade

Water pump not pumping

Check pump motor, check controller

using test mode

Pump hose disconnected

Check hose

Compressor not operating

Check compressor contactor, check

controller using test mode
Check compressor start components,

check PTCR resistance and temperature
Check compressor voltage
Check compressor windings

Low refrigerant charge

Add some refrigerant and restart unit. If

cycle time improves, look for leak.

Hot gas valve leaks through during freeze

Check hot gas valve for hot

outlet during freeze

Thermostatic expansion valve bulb loose

Check bulb

Thermostatic expansion valve producing very

low or very high superheat

Check evaporator superheat, change

TXV if incorrect

Liquid line valve does not open

Check coil of valve, check controller

using test mode

Compressor inefficient

Check compressor amp draw, if low and

all else is correct, change compressor

Debris in refrigeration system

Recover charge. Open quick connects,

check for loose or missing foil. Open

liquid line and hot gas valves. Check for

debris. Replace drier, evacuate and

weigh in nameplate charge.