Pre-Charged Tubing Coupling Connections

Inspect couplings, wipe clean and lubricate both parts

with polyolester refrigerant oil.
Hand tighten to be sure threads are properly engaged.

Use two wrenches and continue tightening the

couplings. As the diaphragms being to pierce, the

couplings will be harder to turn. Be sure only the swivel

nut is rotated.
Continue tightening until the swivel nut feels like it is

tight, then go to the next step. No threads will be seen

when the couplings are tight.

After the swivel nut feels like it is tight, mark the nut and

the panel. Then tighten one quarter turn more. That

ensures that there is a brass-to-brass joint inside the

coupling.