beautypg.com

Scotsman Prodigy Series User Manual

Page 26

background image

January 2015 Page 26

Electrical Component Details

Discharge temperature sensor.
• Thermistor attached to the discharge line near the compressor. Reported temperature used by the controller

to determine end-of-cycle-fan-off-delay time. If discharge temperature exceeds a preset maximum, controller

will shut the machine off.
Note: Controller will operate machine in a default mode with thermistors disconnected from the

controller. Diagnostic code #5 or 7 will be displayed during that time.

Component Indicator Lights
System Indicator Light ON

Condenser Fan or Liquid Line Valve

Fan Motor Powered or LLV open

Water

Pump

Pump

Motor

Powered

Purge

Valve

Purge

Valve

Opens

Inlet Water Solenoid Valve

Inlet Water Valve Opens

Hot

Gas

Hot

Gas

Valve

Opens

Compressor

Contactor

Contactor

Closes

Ready to Harvest

Water contacting ice thickness sensor probe

Sump Empty

Open between mid sensor and common

Sump Full

Closed between top probe and mid probe

Curtain

Switch

Curtain

open