General Installation - Air or Water Cooled

Location Limitations:
The product is designed to be installed indoors, in a controlled environment. Air cooled models discharge

very warm air into the room out the back. Space must be allowed at the left side and back for air intake and

discharge. Water cooled models discharge warm water into the building’s drain. Space needs to be provided

on both sides and above for service access.

Space Limitations
Note: Although the machine will function, ice capacity of air cooled machines will be significantly

reduced with minimal clearance at the sides, back and top. Some space is recommended for service

and maintenance purposes on all models.
6" of space at the sides and back is required for adequate operation. To get the most capacity, locate the

machine away from heat producing appliances and heating ducts.
22 and 30 inch wide models (up to D series: Airflow is in the left side, out the back (as viewed from the front).
22 and 30 inch D series: Airflow is in the front, out the back
48 inch wide models: Air flow is in the front and left side and out the back.

Environmental Limitations
Minimum

Maximum

Air temperature

50

o

F.

100

o

F.

Water temperature 40

o

F.

100

o

F.

Water pressure

20 psi

80 psi

Power supply – acceptable voltage ranges
Minimum

Maximum

115 volt model

104 volts

126 volts

208-230 volt model 198 volts

253 volts

Warranty Information
The warranty statement for this product is provided separately from this manual. Refer to it for applicable

coverage. In general warranty covers defects in material or workmanship. It does not cover maintenance,

corrections to installations, or situations when the machine is operated in circumstances that exceed the

limitations printed above