beautypg.com

Scotsman Prodigy Series User Manual

Page 50

background image

January 2015 Page 50

Problem

Likely Cause

Probable Solution

Shut down on

maximum harvest time

Ice bridge thickness too small, not enough ice

to open curtain

Check and adjust if needed

Ice bridge thickness too large, ice frozen to

evaporator frame

Check and adjust if needed

Purge valve does not open, water melts ice

bridge, not enough ice to open curtain

Check purge valve

Incomplete ice formation

Check water distributor for partially

plugged holes

Curtain out of position

Check curtain for swing restriction

Curtain switch does not open when curtain

does

Check switch with ohmmeter

Hot gas valve does not open

Check hot gas valve, check controller

using test mode

Harvest assist probe out of position – ejector

pin not retracted

Check harvest assist mechanism – spring

should retract pin

Damaged evaporator

Check evaporator surface

Shut down on

minimum freeze time

Grounded ice thickness sensor

Check sensor for dirt and position. Clean

and check gap to evaporator surface

Restricted water distributor

Clean water distributor

Dirty spillway surface

Scrub spillway

Bridge thickness too thin

Adjust to correct thickness

Diagnostics - Remote Air Cooled