Start-up sequence, Tart, Equence – Rena T-950 User Manual
Page 61
SETUP & OPERATION
55
Start-up Sequence
Start up the TABBER in the following sequence:
1. Turn on the tabber using the Main Power Switch [1]
2. Check that the Emergency Stop button/switch [8] is in the operate position (released).
3. Press the Head Power button [2] on the Control Panel.
Tip: If the head power button won’t turn on, check the following: exit roller assembly
closed, tab drive cover closed, and the Safety Stop Jumper or control cable is connected.
If the tabber is being used in-line with other Rena equipment (XPS-ProMail system);
make sure the Emergency Stop switches on the other devices are also released, and the
power on the other in-line equipment is also on.
4. Press the Transport Power button [3] on the Control Panel
5. Press the RUN key [11], located below the soft keys on the Control Panel to start the
tabber.
6. Adjust the Speed Control [5] to set the speed of the Tabber.
7. Press the STOP key [10] located below the soft keys to stop the tabber. Pressing the
large Emergency Stop button [8] will shut down the entire tabber and lock out the other
keys. To restart from an Emergency Stop you must repeat this sequence from Step #1.
NOTE: The maximum speed you can run the TABBER will depend on the number of
tabs you are applying. The speed of the tabber for applying single tabs is 35,000 pieces
per hour, for applying double tabs it is 30,000 pieces per hour and for applying triple tabs
it is 20,000 pieces per hour. Exceeding these speeds will cause the tabber to stop.
After the tabber is setup, the operation of the tabber is the same whether you are tabbing,
applying labels or stamps. For more information, please refer to the “Setup and Operation”
section of this manual.