MovinCool Climate Pro 18 Service Manual User Manual
Page 61

Repair Section
61
Troubleshooting of Insufficient Cooling or Heating - Table 2
< NOTE >
Under heating mode operation, when the room temperature is higher than 68 °F (20 °C), the low
fan speed option is deactivated and switched to medium fan speed to prevent high pressure
protection activation.
Condition
Check Area
Possible Cause
Remedy
Insufficient Cooling
or Heating
No hot air
during
HEAT
mode
operation
LCD display
shows
HEAT
mode, but
operates in
COOL
mode.
F1 fuse (1.5 A)
F1 fuse (1.5 A) is blown.
Replace the F1 fuse
(1.5 A).
4-way valve
4-way valve failure
Replace the coil on the 4-
way valve.