Operation Section

39

5.5 Compressor

(1) Compressor motor

• The compressor motor is a 1 phase, induction type motor and is contained within the same

housing as the compressor.

Specifications:

- Rated Voltage: 115 V, 60 Hz
- Rated Output : 1160 W

(2) Compressor overload relay

• An external compressor overload relay is used

to protect the compressor motor. This relay is
mounted within the connector housing that
attaches to the top of the compressor. The
relay interrupts the flow of current when there is
an overload condition and, high temperature
builds up in the compressor.

5.6 Power Cord with LCDI

• The Climate Pro 18 is equipped with UL recognized LCDI power cord and NEMA plug

configuration (5-20). The appropriate outlet must be used for this plug type. LCDI is used for
monitoring leakage current. Once leakage current is detected, LCDI de-energizes the unit.

Operating Temperature

Non-Operating Limit at 176 °F

(100 °C) (A)

Marking

OFF (Open Contacts)

ON (Closed Contacts)

302 °F (150 °C)

156 °F (69 °C)

19.0

MRA4720-12027

I001691

Bimetal

Terminal

Points

ILL00872-00

Reset Button

Test Button