Operation Section

37

(4) Transformer for relay board

• A dry-type transformer rated 40 VA is equipped

within the unit to provide step down voltage
from 115 V to 20 V.

• Terminals 1 and 5 are connected to 115 V

power source to supply power to secondary
side.

• Terminals 6 and 10 of the secondary side are

connected to the relay board to provide 20 V
output.

Specifications:

- Type: Dry type
- Rated VA: 40 VA
- Power Requirement: 1 Phase, 60 Hz
- Primary Voltage: 115 V
- Secondary Voltage: 20 V

(5) Optional transformer for 24VAC thermostat (field supplied)

• A dry-type transformer rated 40 VA is equipped

within the unit to provide step down voltage
from 115 V to 24 V.

• Terminals 3 and 5 are connected to 115 V

power source to supply power to secondary
side.

• Terminals 6 and 10 of the secondary side are

connected to the signal terminals to provide 24
V output.

Specifications:

- Type: Class 2 transformer
- Rated VA: 40 VA
- Power Requirement: 1 Phase, 60 Hz
- Primary Voltage: 115 V
- Secondary Voltage: 24 V

ILL00879-00

Secondary

20 V

40 VA, 60 Hz

1

5

10

6

4

2

Primary

115 V

ILL00905-00

Secondary

Primary

Connected to
Signal Terminals
(24VAC Neutral,
24VAC Hot)

40 VA, 60 Hz

Connected to
Terminals
(R1, T1)

3

1 0

6

120 V

24 V

3

5

1 0

6