beautypg.com

13 $aa9(data) – Measurement Computing CB-COM-7012 User Manual

Page 36

background image

36

CB-7012, CB-7014, CB-7017 User’s Manual

2.13 $AA9(Data)

Description: Set LED Data

Note: This command is for CB-7012D/12FD/14D only.

Syntax: $AA9(Data)[CHK](cr)

$

Delimiter character

AA

Address of module to set (00 to FF)

9

Command for setting LED data

(Data)

Data for show on the LED, from -19999. to +19999.

The data format is a sign, 5 numerals and a decimal point.

Response: Valid Command:

!AA[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax or communication error may get no response.

!

Delimiter for valid command

?

Delimiter for invalid command or LED not set to host

control.

AA

Address of responding module (00 to FF)

Example:

Command: $019+123.45

Receive: !01

Send Address 01 LED data +123.45, return successful.

Command: $029+512.34

Receive: ?02

Send Address 02 LED data +512.34; returns that the LED is

not set in the host mode.

Related Command:

Sec. 2.11 $AA8, Sec. 2.12 $AA8V

This manual is related to the following products: