CB-7012, CB-7014, CB-7017 User’s Manual
2.12 $AA8V
Description: Set LED Configuration
Note: The command is for CB-7012D/12FD/14D only.
Syntax: $AA8V[CHK](cr)
$
Delimiter character
AA
Address of module to set (00 to FF)
8
Command for setting LED configuration
V
1=Set LED to module, 2=Set LED to host
Response:
Valid Command:
!AA[CHK](cr)
Invalid Command:
?AA[CHK](cr)
Syntax or communication error may get no response.
!
Delimiter for valid command
?
Delimiter for invalid command
AA
Address of responding module (00 to FF)
Example:
Command: $0182
Receive: !01
Set Address 01 LED to host control, return successful.
Command: $0281
Receive: !02
Set Address 02 LED to module control, return successful.
Related Command:
Sec. 2.11, $AA8; Sec. 2.13, $AA9(Data)