2.12 $AA8V

Description: Set LED Configuration

Note: The command is for CB-7012D/12FD/14D only.

Syntax: $AA8V[CHK](cr)

$

Delimiter character

AA

Address of module to set (00 to FF)

8

Command for setting LED configuration

V

1=Set LED to module, 2=Set LED to host

Response:

Valid Command:

!AA[CHK](cr)

Invalid Command:

?AA[CHK](cr)

Syntax or communication error may get no response.

!

Delimiter for valid command

?

Delimiter for invalid command

AA

Address of responding module (00 to FF)

Example:

Command: $0182

Receive: !01

Set Address 01 LED to host control, return successful.

Command: $0281

Receive: !02

Set Address 02 LED to module control, return successful.

Related Command:

Sec. 2.11, $AA8; Sec. 2.13, $AA9(Data)