DSI SS7MD Programmer’s Manual Issue 3

source_stream

The source_stream references the cross connect switch streams that should be used as a source for
data. The parameter takes values in the range of 0 to 31. For some modes (for example, 11 and 12), this
field is used to specify a local stream instead of a switch stream.

source_slot
The source slot references the timeslot from which to connect or disconnect to the cross connect switch
stream. The source slot values are in the range 0 to 127.

dest_stream
The dest_stream references the cross connect switch streams that should be used as a destination for
data. The parameter takes values in the range of 0 to 31.

dest_slot
The dest slot references the timeslot from which to connect or disconnect to the cross connect switch
stream. The dest slot values are in the range of 0 to 127.

6

Remove a duplex connection between two timeslots on the cross connect switch
and one timeslot on the CPU local bus. Use the local_stream and local_slot
parameters to specify both timeslots for disconnection.

8

Remove a connection between a switch timeslot and a CPU local bus timeslot.
Then create a simplex connection between the same CPU local bus timeslot
back to the switch timeslot. Use the local_stream and local_slot parameters to
specify the CPU local bus timeslot, and the source_stream and source_timeslot
to specify the switch timeslot.

11

Make a simplex connection between two CPU local bus timeslots. The
source_stream and source_slot parameters specify the source of the signal in
terms of liu_id and timeslot, respectively. The local_stream and local_slot
parameters specify the outgoing lLIU or CPU stream and timeslot, respectively.

12

Make a duplex connection between two CPU local bus timeslots. The
source_stream and source_slot parameters specify the source of the signal in
terms of liu_id and timeslot, respectively. The local_stream and local_slot
parameters specify the outgoing liu_id and timeslot, respectively

13

Remove a duplex connection between two CPU local bus timeslots. Use the
local_stream and local_slot parameters to specify one timeslot and the
source_stream and source_slot parameters to specify the other.

Value