3 physical interfaces, 4 protocol resource support, Physical interfaces – Dialogic DSI SS7MD User Manual
Page 12: Protocol resource support
12
2 Specification
which to install the board. Refer to
Section 2.2.7, “Airflow Requirements” on page 13
information.
2.2.3
Physical Interfaces
The DSI SS7MDL4 board supports the following physical interfaces:
•
Four T1/E1/J1/J1 digital trunk interfaces. See
below for more detail.
2.2.3.1
T1/E1/J1 Digital Trunk Interface Properties
The properties of the T1/E1/J1 digital trunk interfaces are described as follows:
•
Standard
— Four interfaces each are software configurable as either T1, E1, or J1
— High impedance software selectable
•
Pulse mask
— T1: ANSI T1.403
— E1: ITU-T G.703
— J1: TTC JT-G.703
•
Data rate
— T1: 1544 kbits/s ± 50 ppm
— E1: 2048 kbits/s ± 50 ppm
— J1: 1544 kbits/s ± 50 ppm
•
Frame format
— T1: F4, D3/D4, ESF, and F72/SLC96
— E1: E1 and E1-CRC4
— J1: J1 frame format
•
Line codes
— T1: B8ZS and AMI
— E1: HDB3 and AMI
— J1: B8ZS and AMI
•
Connector type
— RJ-48C
2.2.4
Protocol Resource Support
When used in a signaling node, the DSI SS7MDL4 board supports the Message Transfer Part (MTP) running
on the board and optionally other protocols including MTP3, ISUP, TUP, SCCP, TCAP, MAP, INAP and IS41
running on the host. The protocols are enabled by software licenses. See
Section 2.3, “Software Licenses” on
The DSI SS7MDL4 board supports passive monitoring of HDLC format data links including, for example, SS7,
LAPB, LAPD, ISDN, and DPNSS. In this mode, the received messages are directly reported to the application.
For more information on link monitoring, see
Section 4.6, “Monitoring” on page 34
.
It is possible to use monitor and receive-transmit protocol operations concurrently on the same signaling