6 Message Reference

Note: The option chosen by the user must be appropriate to the actual hardware fitted; otherwise an

error status is returned.

line_code
The line coding technique. The following table shows the permitted values and their meanings.

frame_format
The frame format. The following table shows the permitted values and their meanings.

crc_mode
The CRC mode. The following table shows the permitted values and their meanings.

build_out
The following table shows the permitted values and their meanings.

3

E1 120 ohm balanced interface

4

T1

(including J1)

5

E1 120 ohm balanced interface

Value

Description

1

HDB3 (E1 only)

2

AMI

4

B8ZS (T1/J1)

Value

Description

1

E1 double frame (E1 only)

2

E1 CRC4 multiframe (E1 only)

3

F4 4-frame multiframe (T1 only)

4

D3/D4 (Yellow alarm = bit 2 in each channel (T1 only)

7

ESF (Yellow alarm in data link channel) (T1 only)

8

F72/SLC96 (72-frame multiframe) (T1 only)

9

J1 frame format (liu_type must be 4 [T1])

Value

Description

1

CRC generation disabled

2

CRC4 enabled (frame_format must be set to 2)

4

CRC6 enabled (frame_format must be set to 7)

Value Description

0

Setting for E1 devices

1

T1 default (T1 short haul)

2

T1 short haul 0 - 133 ft

3

T1 short haul 133 - 266 ft

4

T1 short haul 266 - 399 ft

5

T1 short haul 399 - 533 ft

6

T1 short haul 533 - 655 ft

7

Not supported.

8

T1 long haul LB0 (-0dB)

9

T1 long haul LB0 (-7.5dB)