beautypg.com

Dialogic DSI SS7MD User Manual

Page 125

background image

125

Dialogic

®

DSI SS7MD Programmer’s Manual Issue 3

— E1 interfaces have 32 timeslots numbered 0 to 31. Timeslot 0 is used for frame alignment and

timeslot 16 is generally used for signaling or is empty. Hence the normal configuration is to cross
connect timeslots 1 to 15 and 17 to 31 between the two ports on each signaling board by setting the
value to 0xfffefffe.

— T1/J1 interfaces have 24 timeslots, numbered 1 to 24. To cross connect all the timeslots on a T1

interface between the two PCM ports on a signaling board, the value 0x1fffffe should be
used.

In duplex mode both PCM ports should have been previously configured under the same type of PCM
connector T1, E1 or J1.


For DSI SS7MD Boards, not applicable. Set to 0.