4 scbus_listen, Scbus_listen, Connect switch timeslot to liu timeslot – Dialogic DSI SS7MD User Manual
Page 123
123
Dialogic
®
DSI SS7MD Programmer’s Manual Issue 3
7.1.4
SCBUS_LISTEN – Connect Switch Timeslot to LIU Timeslot
Synopsis
This command establishes a connection from the switch to an outgoing timeslot on the Line Interface Unit
(LIU).
Note: Dynamic modification of voice paths can only be performed by issuing messages directly to the
board. The
MVD_MSG_SC_LISTEN
message is recommended for this purpose.
Syntax
SCBUS_LISTEN
Example
SCBUS_LISTEN 0 0 31 23
Parameters
The SCBUS_LISTEN command includes the following parameters:
•
The logical identity of the board in the range from 0 to one less than the number of boards supported.
•
The identifier of the T1/E1/J1
Line Interface Unit (LIU) in the range 0 to one less than the number of
LIUs.
•
The timeslot number on the T1/E1/J1 LIU on which the data from the switch will be transmitted. The
valid ranges are:
— For a T1 interface: 1 to 24.
— For an E1 interface: 1 to 31.
— For a J1 interface: 1 to 24.
•
The channel number on the switch to which the LIU will listen. This should be in the range from 0 to one
less than the total number of channels on the switch.