Modelpreparation, Selectingatibase – Ivoclar Vivadent IPS e.max Press Abutment Solutions v.2 User Manual
Page 8

8
Modelpreparation
For the fabrication of an IPS e.max Press Abutment Solutions restoration, a model with gingiva mask is fabricated.
– Select the suitable model analog according to the implant system used.
– Fabricate a model with gingiva mask.
SelectingaTibase
The following paragraphs outline the selection criteria for a suitable Ti base. As a general rule, the instructions of the
respective manufacturer regarding the use of the Ti base have to be observed.
– Only bases consisting of Ti or Ti alloys must be used.
– Select a Ti base with a size that matches the clinical situation and the chosen implant system. The geometry
requirements must be observed.
– The rotation lock must be designed in such a way that stress concentrations on the pressed object are avoided.
– Ti bases with undercuts, e.g. retention grooves, are suitable to some extent.
– Check the available space for the pressed object taking the geometry of the Ti base into account on the model (e.g.
silicone key).
– Observe the instructions of the manufacturer when modifying the Ti base.
Prepared model with gingiva mask
Minimumdimensions
HeightH
Ti
(bonding surface)
ShoulderwidthS
Ti
Tibase
H
Ti
min.4.0mm
S
Ti
min.0.6mm
Height H
Ti
(luted area)
Marginal shoulder
width S
Ti