Ivoclar Vivadent IPS e.max Press Abutment Solutions v.2 User Manual
Page 41

41
Application
procedure
–
Permanent
Cementation
Apply Multilink Implant directly from the mixing tip in a thin layer on the bonding
surface of the Ti base.
Position the pressed object above the Ti base in such a way that the position markings
are aligned.
Carefully remove excess in the screw cavity, e.g. with a Microbrush or a brush, using a
rotary movement.
Apply a glycerine gel (e.g. Liquid Strip) to the cementation joint to prevent the
formation of a inhibition layer.
Polymerize the luting composite for 7 minutes (optionally in a light-curing unit).
Important: Do not move the objects until the material has completely
cured and hold them in place without allowing for any motion.
Apply Multilink Implant directly from the mixing tip in a thin layer on the bonding
surface of the pressed object.
Join the components using even and light pressure. Subsequently, tightly press the
components together for 5 seconds.
Remove excess carefully in its ductile state, e.g. with a foam pellet, while applying