Select the press program in accordance with the selected ingot to be pressed

and the investment ring size used.

Programat EP 3000

Select the press program in accordance with the selected ingot to be pressed

and the investment ring size used.

Programat EP 5000

The press parameters for HO, MO, LT and HT are integrated starting

with software V 6.1.

The press parameters for HO, MO, LT and HT are integrated starting

with software V 6.1.

Press and Firing Parameters

Press parameters for IPS e.max Press

The press furnace, investment ring size and the selected IPS e.max Press ingot must be considered:

B

t

T

H

V

1

V

2

°C

°C/min

°C

min

°C

°C

700

60

925

15

500

925

Program 11-20

Software 2.9

700

60

930

25

500

930

Program 11-20

Software 2.9

700

60

920

15

500

920

Program 11-20

Software 2.9

700

60

925

25

500

925

Program 11-20

Software 2.9

Press furnace IPS e.max Press

ingots

IPS Investment

Ring System

100 g

200 g

100 g

200 g

EP 500

HO, MO, LT

HT

B

t

T

H

A

°C

°C/min

°C

min

700

60

915

15

300 µm/min

700

60

920

25

300 µm/min

700

60

910

15

300 µm/min

700

60

915

25

300 µm/min

Press furnace IPS e.max Press

ingots

IPS Investment

Ring System

100 g

200 g

100 g

200 g

EP 600
Combi

HO, MO, LT

HT

– The firing parameters listed represent standard values and apply to the Ivoclar Vivadent furnaces P300, P500, P700,

EP 3000 and EP 5000. The temperatures indicated also apply to furnaces of older generations. However, the temperature
in the firing chamber may deviate by approx. ± 10 °C/18 °F, depending on the age of the heating muffle.

– If a non-Ivoclar Vivadent furnace is used, temperature corrections may be necessary.
– Regional differences in the power supply or the operation of several electronic devices by means of the same circuit

may also render adjustments of the temperatures necessary.