Ivoclar Vivadent IPS e.max Press Abutment Solutions v.2 User Manual

Page 19

background image

19

Press­parameters­for­IPS­e.max­Press­

Place the

hot

and loaded investment ring in the centre of the

hot

press furnace using

the IPS Investment Ring Tongs.

Press START to start the selected program.

Once the press program is completed, place the hot investment ring on the cooling

grid using the Investment Ring Tongs and allow it to cool to room temperature.

Then, place the side of the IPS Alox Plunger which has been coated with Separator

into the

hot

investment ring.

The­press­parameters­for­older-generation­Ivoclar­Vivadent­press­furnaces­­

are­listed­on­page­53­under­Press­Parameters.

Select­the­press­program­in­accordance­with­the­selected­ingot­to­be­pressed­

and­the­investment­ring­size­used.

Programat­EP­3000

Select­the­press­program­in­accordance­with­the­selected­ingot­to­be­pressed­

and­the­investment­ring­size­used.

Programat­EP­5000

The­press­parameters­for­HO,­MO,­LT­and­HT­are­integrated­­

starting­with­software­V­6.1.

The­press­parameters­for­HO,­MO,­LT­and­HT­are­integrated­starting­­

with­software­V­6.1.

Application

procedure

­–

­Fabrication

­Hybrid

­Abutment

­and

­Hybrid

­Abutment

­Cr

own