Ivoclar Vivadent IPS e.max Press Abutment Solutions v.2 User Manual
Page 13

13
Procedureforhybridabutmentcrowns:
– If required, re-insert the isolated pin into the screw channel before creating the wax object.
– Design the emergence profile by flooding the area between the gingiva mask and the resin coping with wax.
– Design the abutment crown to full contour according to functional and esthetic criteria. Check in relation to the
opposing dentition.
– Make sure to take a slightly reduced occlusal relief into consideration during the wax-up, since the application of the
Stains and Glaze results in a slight increase in vertical dimensions.
– Remove the object together with the Ti base from the model and check the emergence profile. If necessary, make
adjustments.
– Check the transition to the Ti base and remove possible excess wax.
– Check the required thicknesses (page 9) prior to attaching the sprues.
Application
procedure
–
Fabrication
Hybrid
Abutment
and
Hybrid
Abutment
Cr
own
Design the emergence profile by flooding the area between the gingiva mask and the
resin coping with wax. If necessary, re-insert the pin prior to modelling.
Design the abutment crown to full contour according to functional and esthetic
criteria. Check the object in relation to the opposing dentition.