Options for feeding stay into foils – Harken 7413.10 MKIV Jib Reefing & Furling built after Feb. 2009 User Manual
Page 8

Preassembly
Toggle Deductions/Stay Into Foil Options
8
MKIV units 3, 4
Use dimensions of Harken toggle below to build stay to correct length.
Tip: Turnbuckles should be 1/2 to 2/3
rds
open to allow shortening for new wire stretch and for fine-tuning mast rake.
1. Swage stud at end of wire.
2. Open end of wire and install Norseman or STA-LOK
®
stud after foil is assembled.
3. Rod adapter nosepiece for Harken rod adapter stud: Threaded nosepiece must
have a positive lock as well as adhesive. Use Harken stud with cotter pins.
See page 22.
WARNING! Using a threaded nosepiece with only adhesive at the
upper rod eye terminal may result in headstay system failure.
Make sure there is a mechanical lock.
Unit
Clevis pin Ø
Pin-to-pin length
3
19.1 mm (
3
/
4
")
83 mm (3
9
/
32
")
22.2 mm (
7
/
8
")
98 mm (3
7/8
")
Options for Feeding Stay into Foils
Unit
Clevis pin Ø
Pin-to-pin length
3
19.1 mm (
3
/
4
")
83 mm (3
9
/
32
")
22.2 mm (
7
/
8
")
98 mm (3
7
/
8
")
4
19.1 mm (
7
/
8
")
98 mm (3
7
/
8
")
25.4 mm (1")
115 mm (4
9
/
16
")
28.57 mm (1
1
/
8
")
127 mm (5")
STA-LOK is a registered trademark of Barfield Engineering Company Ltd.