Page 26

background image

26

Vari-Flow Air Management System

FAN 1

HOOD 1

FAN 2

HOOD 2

FAN 3

HOOD 3

FAN 4

HOOD 4

INDIVIDUAL FAN CONTROL

FAN 1

HOOD 1

FAN 2

HOOD 2

FAN 3

HOOD 3

FAN 4

HOOD 4

INDIVIDUAL FAN CONTROL

LIGHTS 1

SYSTEM 1

LIGHTS 2

SYSTEM 2

LIGHTS 3

SYSTEM 3

LIGHTS 4

SYSTEM 4

INDIVIDUAL LIGHT CONTROL

LIGHTS 1

SYSTEM 1

LIGHTS 2

SYSTEM 2

LIGHTS 3

SYSTEM 3

LIGHTS 4

SYSTEM 4

INDIVIDUAL LIGHT CONTROL

Individual light control directs you to the
individual light control page where you can
turn individual lights on or off.

Individual fan control directs you to the
individual light control page where you can
turn individual fans on or off.

Navigation icon will display a submenu
showing alarms, home and settings.

INDIVIDUAL

LIGHT ON/OFF

INDIVIDUAL

LIGHT ON/OFF

INDIVIDUAL
FAN ON/OFF

INDIVIDUAL
FAN ON/OFF

T FAN

50

25

0

SUP

T FAN

FA

50

25

0

SUP

SU

Alarm directs you to the alarms page.

Home directs you to the HOME page (current page shown).

Settings directs you to the main settings page.

Pressing to the left or right side of the ALARM - HOME -
SETTINGS will hide those buttons.

Back arrow returns you to the previous screen.

EXHAUST FANS

SUPPLY FANS

LIGHTS

TEMP INTERLOCK

FIRE

BALANCING

SCHEDULE

BMS

TEMP SENSORS

TRENDING

ALARMS

INFORMATION

SETTINGS, CONFIGURATION & INFORMATION

SETTINGS

CONFIGURATION

INFORMATION

EXHAUST FANS

SUPPLY FANS

LIGHTS

TEMP INTERLOCK

FIRE

BALANCING

SCHEDULE

BMS

TEMP SENSORS

TRENDING

ALARMS

INFORMATION

SETTINGS, CONFIGURATION & INFORMATION

SETTINGS

CONFIGURATION

INFORMATION

EXHAUST FAN 1 DETAILS

TEMPERATURE SENSORS ASSIGNED TO THIS FAN

EXHAUST FAN

SETTINGS HOME

VFD BY OTHERS OR VARI-
GREEN MOTOR USED. NO
FURTHER INFORMATION
AVAILABLE.

FAN NAME:

HOOD 1

DESIGN CFM

3000

CURRENT CFM

0

LOW TEMP SETPOINT

90

°F

HIGH TEMP SETPOINT

115

°F

LOW SPEED

50.0

%

HIGH SPEED

100.0 %

1 2 3 4

EXHAUST FAN 1 DETAILS

TEMPERATURE SENSORS ASSIGNED TO THIS FAN

EXHAUST FAN

SETTINGS HOME

VFD BY OTHERS OR VARI-
GREEN MOTOR USED. NO
FURTHER INFORMATION
AVAILABLE.

FAN NAME:

HOOD 1

DESIGN CFM

3000

CURRENT CFM

0

LOW TEMP SETPOINT

90

°F

90

90

HIGH TEMP SETPOINT

115

°F

115

115

LOW SPEED

50.0

%

50.0

50.0

HIGH SPEED

100.0 %

100.0

100.0

1

2

3

4

Settings

Exhaust Fans allows the user to change the setpoints
for the fan.

Fan Name: User can adjust the “nickname” of the fan
to something such as “HOOD1”.

Design CFM: Set from factory (full speed airflow rate).

Low Temp Setpoint: Temperature at which the speed
of the fan is at the low speed.

High Temp Setpoint: Temperature at which the speed
of the fans is at the high speed.

Low Speed: Speed at which the fan is at when at or
below the low temp setpoint.

High Speed: Speed at which the fan is at when at or
above the high temp setpoint.

Temperature Sensors Assigned: Shows which
temperature sensors are controlling this fan speed.

NOTE

The fans will modulate speed when the temperature is
between the low and high temp setpoints.

General Information

Any field that has a black border with a green fill,
indicates it is editable.

If the field displays a numerical value, a number keypad
will display. After entering the desired value press the
Enter button.

If the field is an alphanumeric value, a standard
keyboard will display. After entering the desired value,
press the Enter button.

The field may also display a multiple choice. After
selecting the desired choice, press the OK button.

®