Standards, Communication standards, Hid reader security standards – Gasboy FHO Pods User Manual
Page 9: Setup, Standards 1.5.1. communication, Hid reader security standards 1.6. setup

(-10°F – 158°F)
Humidity: Operating: 20% to 80%
Storage: 10% to 90%
1.5.
STANDARDS
1.5.1. Communication Standards
The HID Pod communicates over the following standard:
LAN
1.5.2. HID Reader Security Standards
The embedded reader and the cards require matching keys to function. All RF data transmission
between the card and reader is encrypted, using a secure algorithm (extremely secure 64-bit
authentication keys). The key management system reduces the risk of compromised data or
duplicated cards.
1.6.
SETUP
In order to install the HID Pod and configure the unit in FHO, proceed as follows:
1. Place the HID Pod in the office next to the HO PC
2. Connect HID Pod to power supply. The Pod connectors are shown in Figure 1-2. HID Pod,
3. Connect the HID Pod to the PC, utilizing a LAN cable
4. Browse to FHO and select: Administration
5. Select the Tag Acquire Device checkbox
6. Select the TCP/IP radio button
7. Enter the default IP address: 192.168.1.211
8. Enter default Port: 3000
9. Select the HEX radio button
10. Enter the hexadecimal address assigned to the Pod: 46
11. Click on the Save button.
FHO Pods User’s Manual
7
N
N
O
O
T
T
E
E
The FHO’s PC cannot communicate to both the
HID POD and Mifare TAG POD at the same time.