Maintenance, Cleaning, Troubleshooting – Gasboy FHO Pods User Manual
Page 22: Maintenance 2.8.1. cleaning 2.8.2. troubleshooting, Table 2-3. troubleshooting

20
FHO Pods User’s Manual
2.8. MAINTENANCE
This section provides general maintenance and troubleshooting instructions for the MiFare Pod.
2.8.1. Cleaning
C
C
A
A
U
U
T
T
I
I
O
O
N
N
Do not use any solvents such as thinner or benzene.
The MiFare Pod should be cleaned periodically, in order to ensure proper operation.
The cleaning purpose is to remove any dust or foreign body that may harm the reader and
consequently prevent the completion of the tag acquisition process.
Clean the Tag Reader with a damp cloth only.
2.8.2. Troubleshooting
Table 2-3 lists the recommended procedures for troubleshooting the MiFare Pod.
Table 2-3. Troubleshooting
No.
Symptom
Troubleshooting Procedure
Recommended Action
1
Display is off
Check DC Voltage power supply
output
Replace DC Voltage
Power Supply
Check the proper connection between
the Power Supply and MiFare Pod
Connect the PS
connector anew
2 No
communication
between MiFare Pod and
the HO PC
Check RS-232 connection between
the MiFare Pod and the HO PC
Replace MiFare Pod
3
LEDs are not operating
Check DC Voltage power supply
output
Replace DC Voltage
Power Supply