N o H o s t
C o m m u n i c a t i o n
Figure 2-5. MiFare Pod Display – No Communication Message
3. Connect the MiFare Pod to the PC, utilizing the RS-232 harness, to an available COM Port.
The MiFare Pod displays the application version installed and the serial address
(hexadecimal) assigned to the device (see Figure 2-6
O r T R A P P 2 3 2
V e r X . X X . X X ( 3 A )
Figure 2-6. MiFare Pod Display – No Communication Message
4. Set the communication channel to the FHO in Administration → Setup → General tab (see
a. Select the Tag Acquire Device checkbox
b. Select the Serial radio button
c. Enter the COM port in use
d. Select the HEX radio button
e. Enter the hexadecimal address assigned to the Pod, as it appears on the display
Figure 2-7. General Tab – Tag Acquiring Device Section
5. Click on the Save button. The MiFare Pod displays a Welcome message (see Figure 2-8)
We l c o m e
P r e s e n t Y o u r T a g
Figure 2-8. MiFare Pod Display – Welcome Message
The MiFare Pod is now ready for use.