Tag Reader Installation Guide

19

2-5.5.

2-5.5.

Post-Installation

Checks

and

Programming

of

Tag

Reader

Address

Post-Installation Checks and Programming of

Tag Reader Address

Proceed as follows:

1. Restart the CFN PLUS

2. Monitor the power-up indications provided by the Tag Reader:

 Check that the green

and red

indicators turn on for a few seconds and then turn

off.

 Check that a single beep is heard.

 Check that the LCD displays Tag Reader

software version, followed by the welcome
message.

3. Observe the default OrTR address as displayed on the screen as the device is powered-up,

and then set the new OrTR address using the Host ORPT application, as follows:

a. Connect a PC on which the Host OrPT application was previously installed to OrTR

RS-485 connector via 8-Port Commverter or any other RS-485/RS-232 convertor

b. Run the Host OrPT application. The following screen is displayed (see Figure 2-6):

Figure 2-6. Host OrPT Main Screen

c. Click on the Scan button. The Scan/Set New Address dialog box appears (see Figure

2-7)