9

In North America, use a NEC Class 2 power supply, low voltage and low current [maximum
100 VA even under fault conditions]. The adaptor can be installed in the office, in the installation
pole or pedestal, or in a separate box.

The TR is provided with DC connection cables protruding from the rear panel for easy connection.

N

N

O

O

T

T

E

E

If the power supply is installed far from the TR box,
make sure the TR receives a correct voltage! There
may be a power failure on the lines!

1-5.

1-5.

HOUSING

HOUSING

The Tag Reader system enclosure is made of rugged plastic, in the form of a small box. The
enclosure is weather-proof in order to sustain the harsh environment of a Home Base Station. The
devices in its front panel are sealed to prevent humidity and dust penetration.

1-6.

1-6.

SPECIFICATIONS

SPECIFICATIONS

1-6.1. Operational

 User Interface – Alphanumeric LCD

Dual-LED

green

and

red

indicators

Piezoelectric

speaker

Readers -

Contactless MiFare reader

Magnetic card reader (optional)
Payment contactless cards reader (optional)

 Display Type – Backlit alphanumeric LCD with 5×7 dot matrix display units

 Display Size – 2 rows of 16 characters each

1-6.2. Communication Interface

 RS- 485

1-6.3. Physical

 Height – 140 mm (5.1 in.)

 Width – 210 mm (8.3 in.)
 Depth – 38 mm (1.5 in.)

 Weight – 480 gram (1.1 lb.)

(see Figure 1-4).

1-6.4. Power

 Operating voltage - 12 - 24 V DC.