How to access atc mode information, Example of how to view last transaction, Definition/function of atc codes – Gasboy M06875K00X User Manual
Page 19: 100 programming code, 200 inspection mode, 300 view last transaction

MDE-4556 Gasboy ATC Kits M06875K00X Installation Manual • July 2006
Page 19
Programming the ATC Option
How To Access ATC Mode Information
Example of How To View Last Transaction
1
Enter 3-digit keypad code for information type desired
(see
Definition/Function of ATC Codes
below).
2
Press ENTER.
3
Press 1 for Meter Position One information.
4
Press ENTER.
5
Record the information.
6
Continue to press each position number for corresponding position information.
7
Press ENTER.
8
Press F2 to exit ATC Mode.
(Wait for 1-minute timeout if F2 is nonfunctional.)
Definition/Function of ATC Codes
100 Programming Code
Instructions for programming ATC option are given in
200 Inspection Mode
Access this mode to obtain a precise reading of ATC system operation during an actual
transaction. This is the most accurate means of checking ATC system accuracy because
temperature readings are displayed during transaction.
Pure product only: Program a blender for 100%, otherwise the PPU display shows error code
105-product error.
• Money display-shows uncompensated volume
• Volume display-shows compensated volume
• PPU display-shows real-time temperature (in degrees Celsius).
300 View Last Transaction
Access this mode after a transaction. This mode can be used as a basic check to make sure
ATC system is operating properly. Temperature displayed in this mode is an average during
the last transaction. Do not use this mode to verify the accuracy of ATC system.
There are no blender restrictions.
• Money display-shows uncompensated volume.
• Volume display-shows compensated volume.
• PPU display-shows average temperature (in degrees Celsius).