Programming the atc option, How to program each fueling position, Gram use only) – used in – Gasboy M06875K00X User Manual
Page 18
Programming the ATC Option
Page 18
MDE-4556 Gasboy ATC Kits M06875K00X Installation Manual • July 2006
Programming the ATC Option
Switch ON the programming switch located on ATC Controller board (
).
At power up:
• Programmed units will flash “104” and then, normal information.
• Non-programmed units will flash “100” which indicates the units must be programmed
per
How To Program Each Fueling Position
How To Program Each Fueling Position
Note: If programming switch is set to OFF, this procedure will not work.
1
Press 1 0 0.
2
Press ENTER.
Money Position will display “1”.
Money Position shows which meter is selected.
(Meter: 1 through 8)
Volume Position will display “1”.
Volume Position shows which fuel type has been selected.
(Fuel Type: 1-gasoline, 2-diesel)
PPU Position will display “730”.
PPU Position shows which fuel density has been selected for the corresponding meter.
[Fuel Density (kg/m
3
): gasoline-730, diesel-840]
Note: The Fuel Density default is 730.
The software will sequence through each meter position for you to assign the fuel type desired.
3
Select fuel type and press ENTER.
4
Sequence through each meter position and verify desired fuel type by pressing ENTER.
5
Switch OFF the programming switch on ATC controller board (
).
6
Press F2 to exit ATC programming mode.
7
Weights and Measures auditor will put a seal on the programming switch (
).
8
Close electronics door.
1
730
1
PPU Position:
Main Display
Information
Money Position:
Current Meter
Volume Position:
Fuel Type
Fuel Density