Installing the M06228K001 or M06228K002 Kit

Page 6

MDE-4503 Atlas Discharge and Valve Conduit Retrofit Kit • July 2005

Removing

1

Remove the covers to the junctions box. See

Figure 1.

Save bolts for reuse.

Figure 1: Junction Box

2

Mark the valve wire connections to correspond with the red, yellow and black valves wires, to
aid in reconnecting to the correct wire. (If there are two valves, also mark those wires.)

3

Remove and retain the wire nuts to the indicated wires.

4

Loosen the valve conduit unions at the junction box. Reference

Figure 1

.

To remove the discharge line:

5

Disconnect and remove the bolts to the formed flanges to the discharge fitting on the bottom of
the meter and at the unit discharge fitting. See

Figure 2

.