Troubleshooting
01/28/04
4-13
The flourescent lights don’t turn on.
Possible Cause
Checks
Corrective Action
No 115/230VAC feed to
9800Q for light power.
Check if circuit breaker is off
or tripped.
Check if 115/230VAC is being
switched through circuit
breaker.
Check if 115/230VAC is
measured at the LIGHTS
connector on the power
bracket.
Turn breaker on, if off.
Replace circuit breaker if
115/230VAC is not being
switched.
Correct wiring problems if
115/230VAC is not measured.
Loose, burnt out, or damaged
bulb.
Check bulb for damage or
burn marks.
Tighten, if loose. Replace if
burnt out or damaged.
Defective ballast
None.
Replace ballast.
All displays on 9800Q show 01 at the far left of the display.
Possible Cause
Checks
Corrective Action
RAM failure.
None.
Replace RAM IC U19 on CPU
PCB. Replace CPU PCB if
replacing U19 did not fix
problem.
All displays on 9800Q show 02 at the far left of the display.
Possible Cause
Checks
Corrective Action
ROM failure.
None.
Replace ROM IC U18 on CPU
PCB. Replace CPU PCB if
replacing U18 did not fix
problem.
STANDALONE MODE ERROR HANDLING
When operating the pump/dispenser in standalone mode (not connected to a fuel management system), the
9800Q displays two-digit error transaction codes on the LCD displays when transactions are terminated
abnormally (by a means other than turning off the pump handle).
There are four possible error conditions that may be displayed:
Code Condition
55 Power
failure
56 Pulser
error
57 Timed
out
58 Limit
cutoff
The error codes are displayed for two seconds at the left of the LCD window, alternating with a five second
display of the last sale amount. The display alternates between the two until a new transaction begins.
When an error occurs, the user should note the error code and relay the information to the system
administrator.
Transaction error codes are displayed only when the pump/dispenser is operating in standalone mode.
When connected to a fuel management system, (on-line mode), transaction error codes are transmitted
back to the fuel management system with the completed transaction data.