Troubleshooting

01/28/04

4-5

9800Q won’t activate in on-line mode. When the pump handle is thrown, the displays do
not go through reset sequence.

Possible Cause

Checks

Corrective Action

9800Q is not communicating
to the GASBOY CFN system.

Verify that the 9800Q is
communicating.

Perform actions listed under
9800Q is not communicating
to the GASBOY CFN System.

9800Q won’t activate in
standalone mode.

Verify that the 9800Q works in
standalone mode..

Close SW1-2 on the CPU
PCB, turn the power off and
on, then perform the actions
listed under 9800Q won’t
activate in standalone mode.
Open SW1-2, then turn the
power off and on before
returning to this page.

CFN system data loaded
incorrectly.

Verify that all CFN system
data is loaded correctly
(authorization codes, product
codes, pump table, etc.)

Reload system data, if
incorrect.