Troubleshooting Table

Reference

Remedy

Possible cause

Symptom

-

Connect the system
to the mains.

System not connec-
ted to mains.

The system cannot
be started after
switching on.

-

Replace fuse below
power switch.

Fuse is blown.

-

Close the covers.

A cover is opened.

Loading Envelopes

on page 66

Check envelope feed
adjustments. Place
envelopes correctly in
hopper.

Envelopes stacked
reversed in the hop-
per.

System stops with
envelope at insert po-
sition (flap not open).

Envelope Specifica-
tions

on page 144

Store envelopes ac-
cording to specifica-
tions.

Envelope flap sticks.

Envelope Specifica-
tions

on page 144

Change envelopes
according to specific-
ations.

Wrong envelope type
used (not according
to specifications or
job settings).

Loading Envelopes

on page 66

#

Adjust envelope sep-
aration.

Envelope separation
not correctly set.

Envelopes are double
fed.

Loading Envelopes

on page 66

#

Check and replace if
needed.

Envelopes not placed
properly in the hop-
per.

Loading Envelopes

on page 66

#

Check side guides
and adjust if needed.

Side guides of the
envelope hopper are
set too wide.

Envelope stops
skewed.

Loading Envelopes

on page 66

#

Refill hopper.

Hopper almost empty.

Envelopes are fed ir-
regularly.

Loading Envelopes

on page 66

#

Adjust envelope sep-
aration.

Separation set too
narrow.

Loading Envelopes

on page 66

#

Check side guides
and adjust if needed.

Side guides set too
narrow.

Loading Envelopes

on page 66

#

Reposition the envel-
ope support.

Envelope support not
positioned correctly.

10

English

137