Stop on misread: defines if the system should stop or not when a code is misread.

In case of “on”, the system stops after a misread. The incorrect set is diverted. After
resetting the system, the final part of the set is also diverted and the system starts
processing again. The diverted set should be checked by the operator. When “Stop
on misread” is set to “off”, the system does not stop after a misread. The incorrect
set is diverted. The final part of the set is also diverted and then the system starts
processing again. After 5 misreads in a row, the system stops and an error code is
generated.

Reverse

reading: (not applicable for OCR)

With

Reverse reading the decision of inserting a mailset is marked on the next set.

For

example with OMR the insert mark is printed on the first page of the set. The

system

will detect the end of a set by detecting the first page of the next set. For

example

in case of BCR using the Customer ID to complete a set. If the ID changes,

the

set is inserted.

In

case the feeder runs empty, the last set is still on the collator because the beginning

of

the next set could not be detected. In this case the feeder empty message contains

an

[Ignore]

function. Tap [Ignore] and the set on the collator will be inserted.

Because

of the feeding and collating principle reverse reading has the following

limitations:
-

The last mark of the code should be printed maximally 85 mm (3.3 inch) from the

top.
-

Enclosures and selective enclosures cannot be handled. When a Thin Booklet

Feeder module is added to the system configuration, enclosures and selective
enclosures

can be handled with reverse reading.