beautypg.com

Formax 6900 Series User Manual

Page 13

background image

12/40

12/40

12/40

12/40

Fig. 18

Feed one envelope

Feed one envelope

Feed one envelope

Feed one envelope
With this function the proper feed of envelopes can be

tested. First carry out the envelope hopper adjustments, see

section 5.7 on page 17. Then put a stack of envelopes in

the hopper. Use key 1 or key 2 to feed one envelope onto

the insert table. Each time the key is pressed a new

envelope will be fed. No insertion will take place.
The “feed one envelope” function can be used when

adjusting the envelope stop position, see “Envelope stop

position adjustment” on the next page.

Insert one document

Insert one document

Insert one document

Insert one document
With this function the proper functioning of the whole

document and envelope transport will be tested. First carry

out all adjustments, see section 5.7 on page 17. Then load

the system with documents and envelopes.
Use key 3 to make one insert cycle. Each time the key is

pressed another insert cycle will be made. When there is no

envelope waiting on the insert table, the machine feeds one

envelope waiting on the insert table. The document will be

inserted and filled envelope is ejected.

If there are documents on the collating area, these

documents will be inserted and the filled envelope is ejected

(and counted). If there is an empty envelope in the inserter,

this envelope will be ejected.
See notes mentioned in section 6.2 on page 22.

Fig. 19

Envelope stop position adjustment

Envelope stop position adjustment

Envelope stop position adjustment

Envelope stop position adjustment
The flap folding line must be positioned under the green

indicator B (Fig. 19). This indicator can be seen after

opening the transparent cover and releasing and lifting the

loc by pulling the release handle of the loc (see page 5).
If necessary, adjust the folding line position by pressing “to

the right” (key 4) or the “to the left” (key 5). Each press

stops the next envelope 1 mm (0,04 inch) to the right (later)

or left (earlier).
Adjustments to the envelope stop position can be made with

the system operating.

Key

1

2

3

4
5
6

#N