1. Make sure valve is bypassed or in a safe condition.
2. Disconnect the power and air supply to the unit.
3. Remove the main cover.
4. Remove the plastic board cover by removing the three retaining screws (see Figure 16).
5. Remove the retaining screw from the main PCB assembly.
6. Remove the five wire connections from the main PCB assembly and lift the main PCB out of the
housing.
7. Remove the four screws from the regulator base. Verify that as regulator is removed, the O-ring
and filter remain in the counter-bore.
8. Remove tubing and barbed fitting from the regulator base.
9. Install barbed fitting and tubing to the new regulator.
10. Verify O-ring and filter are in the counterbore. Install new regulator using 8-32 x 1/2" screws.
NOTE:	Do	not	mix	the	regulator	with	those	from	older	Logix	positioners.	Older	models	contain	
regulators	with	different	settings	that	will	not	work	in	the	Logix	3400IQ model.	The	regulator	
pressure	setting	is	printed	on	the	top	of	the	regulator.	The	Logix	3400IQ regulator	is	set	to	17.4	
psig.
11. Reinstall the five wire connections.
12. Install the main PCB into the housing. Insert the retaining screw through the board into the
threaded boss and tighten evenly, using a Phillips screwdriver. Do not overtighten.
13. Install the plastic board cover. Insert the three retaining screws through the plastic cover into the
threaded	boss	and	tighten	evenly,	using	a	Phillips	screwdriver.	Do	not	overtighten	(see	Figure	
16).	
14. Reinstall all covers.
8.3
Checking or Setting Internal Regulator Pressure
To	check	or	set	the	internal	regulator	pressure,	refer	to	Figure	17	and	proceed	as	outlined	below.	The	
tools	and	equipment	used	in	the	next	procedure	are	from	indicated	vendors.	The	following	tools	are	
required:
• Calibrated pressure gauge (0 to 30 psi)
•
1
⁄
16
" flexible tubing
• Barbed Tee (Clippard Minimatic part number T22-2 or equivalent)
•
3
⁄
32
" Allen wrench
•
3
⁄
8
" open-end wrench