3unpacking and storage, 1 unpacking, 2 storage – Flowserve 3400IQ Digital Positioner User Manual
Page 5

Logix 3400IQ Digital Positioner FCD LGENIM3401-00 – 06/06
flowserve.com
3
Unpacking and Storage
3.1
Unpacking
1. While unpacking the Logix 3400IQ positioner, check the packing list against the materials
received.	Lists	describing	the	system	and	accessories	are	included	in	each	shipping	
container.
2. When lifting the system from the shipping container, position lifting straps to avoid damage to
mounted	accessories.	Systems	with	valves	up	to	six	inches	may	be	lifted	by	actuator	lifting	ring.	
On	larger	systems,	lift	unit	using	lifting	straps	or	hooks	through	the	yoke	legs	and	outer	end	of	
body.
c
WARNING:	When	lifting	a	valve/actuator	assembly	with	lifting	straps,	be	aware	the	
center	of	gravity	may	be	above	the	lifting	point.	Therefore,	support	must	be	given	to	
prevent	the	valve/actuator	from	rotating.	Failure	to	do	so	can	cause	serious	injury	to	
personnel	or	damage	to	nearby	equipment.
3. In the event of shipping damage, contact the shipper immediately.
4. Should any problems arise, contact a Flowserve Flow Control representative.
3.2
Storage
Control	valve	packages	(a	control	valve	and	its	instrumentation)	can	be	safely	stored	in	an	enclosed	
building	that	affords	environmental	protection;	heating	is	not	required.	Control	valve	packages	must	
be	stored	on	suitable	skids,	not	directly	on	the	floor.	The	storage	location	must	also	be	free	from	
flooding,	dust,	dirt,	etc.
Long Term Storage of Logix 3000 series Positioners in Humid Locations
The	Logix	3000	series	positioners	are	designed	to	operate	in	humid	environments	when	connected	
to	a	proper	instrument	air	supply.	There	are	some	occasions	when	valves	and	positioners	are	stored	
at	job	sites	or	installed	and	commissioned	and	then	left	without	instrument	air	for	months.		To	make	
startup	easier	for	units	that	are	left	without	instrument	air	and	insure	that	the	positioners	will	be	
ready	to	operate,	it	is	recommended	that	the	vent	assembly	of	the	positioner	be	sealed	preferably	
with	a	desiccant	pouch	sealed	with	the	vent	assembly.