- 24 -
5) Click on “Save and Exit” to save the entered combinatorial event definition and
Exit, or click on “Save and Add” to continue to enter additional events, or click
on “Cancel” to exit without saving.
Note: “Available” for the event definition will be set to Disabled if an source
event entered in step 4 above does not exist or has been misspelled. To correct,
select edit to re-enter the source event name(s).
The individual components of the entered combinatorial definition are monitored
on a real-time basis by the Event Monitor Table. When the current states of the
components cause the definition to become true, the GPO assigned in the Event
Monitoring Table will be controlled by the “ON Function”. When the current
states of the components cause the definition to become false, the assigned GPO
will be controlled by the “OFF Function”.
3)
EDIT a Combinatorial Event Definition
1) Click on the Edit link near the top of the table. The selection screen will be
displayed.
2) Click the “All” box to edit all combinatorial event definitions OR click on the
desired event definition to edit.
3)
Click on “Edit” to edit the selected items, or c
lick on “Back” to return to the
previous screen.
4) For each row selected, make the desired changes using the pull down menus.
5)
Click on “Save” to save the edited items, or click on “Back” to return to the
previous screen without saving the changes.