D. -P VERSION… PBUS INPUT OUTPUT OPTION (PBIO)

PBIO ENABLE/DISABLE

Press the {PBIO} softkey to enable or disable PBIO. When

disabled the ST400 will ignore all Pbus commands. When
enabled, the ST400 will respond to all Pbus commands.
When enabled and Pbus commands are received, the softkey’s
LED will flash.

PRODUCTION SWITCHER PBIO TRIGGER VALUES

The Production Switcher outputs a Peripheral Bus trigger at

specific Timeline key frames, as programmed by the operator.
The 2044CL performs a specific function for each trigger value:

Grass Valley Group Production Switcher

Trigger Value

Mode

0

Play (if OUT point is specified, stop at
OUT, if clip ends with “*”, Loop Play)

1

Recue to beginning of clip

2

Slo-mo using ST400 Preset Speed

3

Reverse Play

4

Still Frame

5

Loop (Odetics mode only)

6

Record

7

Fast

Forward

8

Fast

Rewind

9 or greater

Play

Sony Production Switcher

Trigger Value

Mode

0

Recue to beginning of clip Play

1

Play (if OUT point is specified, stop at

OUT, if clip ends with “*”, Loop Play)

2

Slo-mo using ST400 Preset Speed

3

Reverse

Play

4

Still

Frame

5

Loop (Odetics mode only)

6

Record

7

Fast

Forward

8

Fast

Rewind

9 or greater

Play

To control more than one VTR, enable the Peripheral Device Address
for each VTR. The Trigger value will be sent to the enabled devices.
OR
GANG the required VTRs on the ST400. See FUNCTION TABLE for

GANG instructions. Enable the Peripheral Device Address for one of
the GANGed VTRs. The Trigger will be sent to the enabled VTR. The

other VTRs in the GANG will perform the same action.

Page

2

2

4

4

o

o

f

f

3

3

9

9

2044CL Instant Clip Access System