14.

A.
B.

C.

D.

15.

VIEW COUNTDOWN TIME (AMP PROTOCOL

ONLY)

Press {RT} softkey to enable the countdown mode on the current channel.

The countdown time is displayed on the first line of the display. The

countdown time is the remaining time till the OUT point, or, if the OUT
point is not marked, till the end of the clip.

If the OUT point is marked and the playout continues passed the OUT

point, the negative countdown is displayed.

Press {RT} softkey to disable the countdown mode on the current

channel.

NOTE: When RT mode is selected, the IN and OUT point are still

marked in either TM or LTC mode, depending on which mode is
selected by

[TIME MODE] key.

BVW MODE

If you wish to control a tape machine or a DDR with the 2044CL-AMP
system, select control MODE=BVW (see Setup Menu section). In this
mode, the media is accessed by timecode, not by clip names. The

cuepoints in BVW mode consist only of IN point, OUT point and Gang
information.
The following functions are not available in BVW mode:

-

View Clip ID

-

Recue Clip

-

Loop Clip

-

Capture

-

Create Clip

-

Create Subclip

All other functions work as described in the manual.