beautypg.com

Shotbox shotkey maps, Shotbox control switches, Clear single cuepoint – DNF Controls 2034CL-O-PBIO vs.3.1 User Manual

Page 20

background image

20

2034CL-O, Vs. 3.1, 300 Clip Instant Access System, Odetics Protocol,

PBIO Option

20. SHOTBOX SHOTKEY MAPS

The SWITCHES on the SHOTBOX access the SHOTLIST locations as follows:

BANK 0, SWITCHES 1 Î 30 access Cue Points 001 Î 030 and e-mem registers 1 - 30.
BANK 1, SWITCHES 1 Î 30 access Cue Points 101 Î 130 and e-mem registers 31 - 60.
BANK 2, SWITCHES 1 Î 30 access Cue Points 201 Î 230 and e-mem registers 61 - 90.
BANK 3, SWITCHES 1 Î 09 access Cue Points 301 Î 309 and e-mem registers 91 - 99.
MARK 3, SWITCHES 10 Î 30 access Cue Points 310 - 330
BANK 4, SWITCHES 1 Î 50 access Cue Points 401 Î 430.
BANK 5, SWITCHES 1 Î 30 access Cue Points 501 Î 530.
BANK 6, SWITCHES 1 Î 30 access Cue Points 601 Î 630.
BANK 7, SWITCHES 1 Î 30 access Cue Points 701 Î 730.
BANK 8, SWITCHES 1 Î 30 access Cue Points 801 Î 830.
BANK 9, SWITCHES 1 Î 30 access Cue Points 901 Î 930.


21. SHOTBOX CONTROL SWITCHES


a. [PLAY]: Plays out the selected clip.

b. [RECUE]: Returns to the beginning of the clip.

d.

[STOP]: Stops playout of the clip.

e.

[SHIFT] + [SHOTKEY]: Clears the contents of the pressed shotkey.


22. CLEAR SINGLE CUEPOINT

On the Shotbox, press [SHIFT] + the Shotkey, the content of which you wish to clear.
The Shotkey becomes blank, the corresponding cuepoint is cleared.