12. TRIGGER
The operator fires a trigger using either the Timeline or Run function on the production switcher.
The ST300 puts the Video Server into the following modes based upon the trigger value:
GRASS VALLEY GROUP VALUES
Trigger
Value
Mode
0
Play
1
Recue to beginning of clip
2
Slo-mo using ST300 Wheel Preset or T-Bar Speed
3
Reverse Play
4
Still Frame
5
Loop
6
Record
7 or greater
Play
SONY VALUES
Trigger
Value
Mode
0
Recue to beginning of clip
1
Play
2
Slo-mo using ST300 Wheel Preset or T-Bar Speed
3
Reverse Play
4
Still Frame
5
Loop
6
Record
7 or greater
Play
To control more than one VTR, enable the Peripheral Device Address for the required VTRs. The
Trigger will be sent to the enabled devices.
OR
GANG the required VTRs on the ST300. Refer to the Function Table for GANG instructions.
Enable the Peripheral Device Address for one of the GANGed VTRs. The Trigger will be sent to