Setting the in (out) points, Create cue point labels, On the st300 – DNF Controls 2034CL-O-PBIO vs.3.1 User Manual
Page 15: A. marking the in (out) points, B. entering the in (out) points, C. viewing the in (out) points, D. clearing the in (out) points

15
2034CL-O, Vs. 3.1, 300 Clip Instant Access System, Odetics Protocol,
PBIO Option
13. SETTING THE IN (OUT) POINTS
a.
MARKING THE IN (OUT) POINTS
1)
Locate the clip to the desired IN (OUT) time.
2)
Press [IN] ([OUT]) to set the IN (OUT) Point. The IN (OUT) indicator will
turn on.
The display will show “IN (OUT) xx:xx:xx:xx” where xx:xx:xx:xx is the saved
time.
b.
ENTERING THE IN (OUT) POINTS
1)
Press [SHIFT] + [IN] ([OUT]) to manually enter a new IN (OUT) time.
2)
Press [ENTER] to save the entered time or press [ESC] to exit without saving.
OR
Press [RECUE] to search to viewed point.
c.
VIEWING THE IN (OUT) POINTS
When the IN (OUT) indicator is on,
press [IN] ([OUT]) to view the existing IN (OUT) Point.
d.
CLEARING THE IN (OUT) POINTS
Press and hold [DEL], then press and release [IN] ([OUT]).
The IN (OUT) indicator goes off.
14. CREATE CUE POINT LABELS
Use
LABEL mode to assign meaningful names to cue points. Rather than viewing cryptic CLIP
IDS on the Shotkeys, LABEL provides a faster and easier method to select cue points.
ON THE ST300
a.
Select cue point to label.
b.
Press the [SHIFT] + [CLIPLIST]
c.
Manually enter a label, up to 12 characters in length, using the numeric keypad,
ST420 Shotbox QWERTY Keyboard, or PC keyboard. (KBIO OPTION)
d. Press the [LOAD] shotkey on the Shotbox to assign the entered label to the
selected cue point
OR
[ENTER] on the ST300
OR
[ENTER) on the PC Keyboard (KBIO OPTION)
OR
[ESC] to exit without save
NOTE: Labels are saved in non-volatile memory in the ST300, not in the Shotbox. They are not
saved in the video server.