beautypg.com

Appendix a specifications – Comtest Networks MTAS-192 METALLIC TEST ACCESS SYSTEM User Manual

Page 47

background image

CT-IG-MTAS192-2008-v1_8.doc

Comtest Networks

MTAS-192

June 2006

Installation Guide

41

Appendix A
Specifications

MTAS-192 Specifications

Table 14: MTAS-192 Specifications

Item Description

Dimensions

3 rack unit high chassis (H x W x D = 5.22" x 17.3" x 10.5")

Mounting

19" or 23" rack-mountable

Chassis Capacity

192 (2-wire) circuit packs

Line Card Capacity

Each line card contains 24 2-wire circuit ports. Up to 8 line
cards can be installed in a chassis.

Line Card Functionality
Options

Test Access only to data or POTS circuits

Splitter only

Splitter plus test access

Slots

8 available for line cards (#1-8)

1 available slot for control module card (#9)

Impedance

North American : 900-600 ohms

ETSI European Harmonized

Line Card
Compliances

MT-5820 and NA-5820 line cards:

T1.413, G.992.1, G.992.3, G.992.5

EU-5807 line card:

TS 101 952-1-1, TS 101 952-1-2

Test Access Capacity

2 four-wire test buses per chassis or daisy-chained system.
Each bus carries both the DSLAM/EQUIPMENT side and
the LINE/FACILITY side of the port under test.