4.1.3 xDSL Filter Card Connectors

The xDSL Splitter and Splitter with Test Access line cards have one female RJ-21
connector labeled "DSL".

Table 10: Connectors of the xDSL Filter Cards

Connector Description

DSL

50-pin (25 pair) RJ-21 female connector – one per line card
slot - for connection to DSLAM.

4.2 Cabling

Refer to Table 11 for a summary of the recommended cables required for installation.

Table 11: MTAS-192 Shelf Cabling Requirements Summary

Interface Cable

Requirements

Recommendations

COMM 1 and
COMM 2

8-wire STP CAT5

STP CAT5 assembly

TAPs

8-wire UTP or STP CAT5

STP CAT5 recommended

DATA 1 and
DATA 2

8-wire UTP or STP CAT5

STP CAT5 recommended

Alarm Jacks

4-wire UTP CAT3

Normally open (NO) dry contacts

Power Terminal
Blocks

#16 - #18 AWG solid or
stranded copper wire

Fuse should be 0.5 Amp for
48 VDC circuit

Ground Screw

#14 AWG solid copper wire

RJ-21 Connectors

UTP or STP CAT5 or CAT3
cable with non-shielded
housing. Minimum #26 AWG
to be used.

Ethernet

8-wire UTP or STP CAT5

STP CAT5 recommended

COM 1

For debug purposes only

AUX 1

8-wire UTP or STP CAT5

STP CAT5 recommended