Comtest Networks MTAS-192 METALLIC TEST ACCESS SYSTEM User Manual

Page 21

background image

CT-IG-MTAS192-2008-v1_8.doc

Comtest Networks

MTAS-192

June 2006

Installation Guide

15

Each MTAS shelf requires three (3) Rack Units or 5.25 inches of vertical rack space.
The MTAS shelves may be installed directly above or below one another: there is no
vertical spacing required for cooling or cabling.

2.8 Unpacking

The MTAS is shipped in two separate boxes – one contains the MTAS-192 shelf, and
the other contains the circuit packs for the shelf. There are no special handling
requirements for the shelf; however, the circuit packs require standard ESD handling
precautions.

CAUTION: A grounded wrist strap should be worn at all times when handling the circuit
packs. Place cards in or on static bags when working with the cards.

NOTE: After unpacking, do not install the circuit packs into the shelf before the shelf is
mounted in the equipment rack. Mount the MTAS-192 shelf in the rack before inserting
circuit packs.

2.9 Inspection

Step 1. Using standard ESD handling precautions unwrap circuit cards one at a time.
Step 2. Consult the packing list (see section 2.10 Packing List) to verify that all items

have been received as ordered and inspect them for obvious physical damage.

Step 3. If there is damage, re-pack the item in the shipping materials in which it came

in and return to Comtest Networks using the standard defect return procedure
in Appendix B: Repair and Return Services.

Step 4. If there is no damage, go to Chapter 3: Installing the MTAS Shelf.

2.10 Packing

List

Please verify the contents of your MTAS-192 shipment against the packing list(s).

2.10.1 Shelf

• One (1) MTAS-192 High Density, Test Access Shelf

• Two (2) universal ANSI ear mounts (flanges) for either 19 or 23" shelves, each

supplied with two (2) screws and two (2) washers

• One (1) ISCL bus terminator (RJ-45 connector 'dongle')

• One (1) Steward EMI (Electro-magnetic Interference) suppressor

• Optional Redundant Power Feed Steward EMI suppressor

• Optional RJ-21 Hex Nut kits

• Optional RJ-21 Angle Shroud kits.


NOTE: Hex Nut and Angle Shroud kits are based on the RJ-21 shroud type (D-type or
Angled) and screw length (0.75" or less than (<) 0.75") used to build the CAT5 RJ-21
24-pair cables that connect to the MTAS backplane POTS, Line, and line card DSL