Rtu (test head) – Comtest Networks MTAS-192 METALLIC TEST ACCESS SYSTEM User Manual

Page 16

background image

Comtest Networks

CT-IG-MTAS192-2008-v1_8.doc

MTAS-192

10

Installation Guide

June 2006

Each splitter card has five (5) modes, which are explained below.

Table 6: Splitter Card Modes

Mode Description

TL1

Command

1

Transparent/
Isolated

In this mode, all test connections are
released. This is the default mode.

DISC-TACC

Loop-around

In this mode, the AF and AE sides of a
TAP are looped back at the line card.

CONN-LPACC-MET

High-impedance
Monitor

This mode uses the AF portion of the TAP
bus and performs a hitless connection to
provide access for monitoring.

CONN-TACC-MET

Bridged Monitor

This mode connects the AF pair directly to
the circuit under test.

CONN-MON

Split

Split Mode access breaks the cable pair to
be tested in two directions, one provided
by AF (towards the customer) and AE
(towards the equipment).

CHG-SPLIT

Figure 10: Transparent/Isolation Mode


1

TL1 commands are explained in the MTAS-192 User Guide.

Facility Side (F)
(Downstream)

AF

Equipment Side (E)
(Upstream)

AE

PSTN

Class 5

DSLAM

Splitter

MTAU (MTAS-192)

Tip

Tip

Ring

Ring

T

T

R

R

2–Wire Circuit

Access Point

RTU (Test Head)